Air Insulated Switchgear
voltage of 6 kV and 10 kV
Request price on «KSO-313SF » or contact our manager a convenient way for you
Description
Series KSO-313SF switchgear of unilateral maintenance, with load-breaking switch in SF6 insulation are designed for switching of 3-phase, 50 Hz, 6, 10 kV rated voltage and up to 1000 A rated current circuits with neutral insulated or earthed via resistor or via an arc-suppression coil.
KSO-313SF switchgear devices are used to assembly switchgear RP (KRU) for receipt and distribution of electric power. The KSO switchgear operation principle is determined by an aggregate of circuits of the main and auxiliary circuits.
Specifications
Rated voltage, kV | 6; 10 |
Rated operating voltage, kV | 7,2; 12 |
Rated current of the main circuits of switchgear with load-breaking switch, A | 630; 1000 |
Rated current of collecting buses, A | 630;1000 |
Rated operating current of switchgear with fuses, A | 16;20;31,5;40;50; 63;80;100;160 |
Rated short-time withstand current for 1 second, kA | no less than 10 |
Rated electrodynamic current of the main circuits, kА | no less than 25 |
Rated voltage of AC and DC control and alarm protection circuits, V | 110;220 |
KSO switchgear inner lighting circuits, V | 12;36 |
Climatic modification and placement category | У3 (N3) |
KSO overall dimensions ( width х depth х height) | 500х940х1900 |
OVERALL DIMENSIONS

A | B | H | |
---|---|---|---|
Gabarit 1 | 500 | 940 | 1900 |
Схемы первичных соединений КСО-313

Symbol structure
Product name: Switchgear of unilateral maintenance
Modification number and year: 313SF.
The main circuit diagram part No.
Drive type:
- м – motor
- т - with preliminary cocking of spring;
- н – manual control
Overall dimensions:
- 1 – dimensions 1;
- 2 – dimensions 2
У3 (N3) – climatic modification
SF modification classification
Classification attributes | Design |
---|---|
Insulation level according to GOST 1516.1 | With standard and reduced insulation |
Presence of the main circuit current-carrying bus insulation | With insulated and non-insulated buses |
Collecting bus system | With one collecting bus system |
Servicing conditions | With unilateral maintenance |
Type of high-voltage lead-in lines (connections) | Cable and busbar |
Ingress protection according to GOST 14254 | IP20 - for front and sides; IP00 - for the rest part of switchgear |
-
Come - we will pay
Travel expenses, airfare, hotel at our expense
The promotion is valid until December 1, 2016 -
Delivery at our expense
When ordering the equipment in the amount of 5 mln. rub.
The promotion is valid until December 1, 2016 -
Electrical equipment leasing
Choose the right program
-
Come - we will pay
Travel expenses, airfare, hotel at our expense
The promotion is valid until December 1, 2016 -
Delivery at our expense
When ordering the equipment in the amount of 5 mln. rub.
The promotion is valid until December 1, 2016 -
Electrical equipment leasing
Choose the right program