+7 351 239-90-31

Air Insulated Switchgear

voltage of 6 kV and 10 kV
Air Insulated Switchgear

Request price on «KSO-313SF » or contact our manager a convenient way for you

Description

Series KSO-313SF switchgear of unilateral maintenance, with load-breaking switch in SF6 insulation are designed for switching of 3-phase, 50 Hz, 6, 10 kV rated voltage and up to 1000 A rated current circuits with neutral insulated or earthed via resistor or via an arc-suppression coil.

KSO-313SF switchgear devices are used to assembly switchgear RP (KRU) for receipt and distribution of electric power. The KSO switchgear operation principle is determined by an aggregate of circuits of the main and auxiliary circuits.

Specifications

Rated voltage, kV 6; 10
Rated operating voltage, kV 7,2; 12
Rated current of the main circuits of switchgear with load-breaking switch, A 630; 1000
Rated current of collecting buses, A 630;1000
Rated operating current of switchgear with fuses, A
16;20;31,5;40;50; 63;80;100;160
Rated short-time withstand current for 1 second, kA no less than 10
Rated electrodynamic current of the main circuits, kА no less than 25
Rated voltage of AC and DC control and alarm protection circuits, V 110;220
KSO switchgear inner lighting circuits, V 12;36
Climatic modification and placement category У3 (N3)
KSO overall dimensions ( width х depth х height) 500х940х1900

OVERALL DIMENSIONS

Габаритные размеры КСО 313SF
  A B H
Gabarit 1 500 940 1900

Схемы первичных соединений КСО-313

Схемы первичных соединений КСО-313

Symbol structure

KSO - 313SF - ХX - Х - УЗ

Product name: Switchgear of unilateral maintenance

Modification number and year: 313SF.

The main circuit diagram part No.

Drive type:

  • м – motor
  • т - with preliminary cocking of spring;
  • н – manual control

Overall dimensions:

  • 1 – dimensions 1;
  • 2 – dimensions 2

У3 (N3) – climatic modification

  • Come - we will pay

    Travel expenses, airfare, hotel at our expense

    The promotion is valid until December 1, 2016

  • Delivery at our expense

    When ordering the equipment in the amount of 5 mln. rub.

    The promotion is valid until December 1, 2016

  • SF modification classification

    Classification attributes Design
    Insulation level according to GOST 1516.1 With standard and reduced insulation
    Presence of the main circuit current-carrying bus insulation With insulated and non-insulated buses
    Collecting bus system With one collecting bus system
    Servicing conditions With unilateral maintenance
    Type of high-voltage lead-in lines (connections) Cable and busbar
    Ingress protection according to GOST 14254
    IP20 - for front and sides; IP00 - for the rest part of switchgear

    Reviews

    ООО «Терра Груп» выражает Вам благодарность и признательность за качественную, своевременную поставку и гарантийное обслуживание оборудования – Подстанции трансформаторной комплектной на напряжение 10 кВ типа КТПН-БПКК-160/10/0,4 и за внимательный подход к поставленной задаче. Мы верим в сохранение сложившихся деловых и дружеских отношений, надеемся на дальнейшее взаимовыгодное сотрудничество. Желаем успешного развития и достижения новых вершин в бизнесе.

    Read completely

    Photo

  • Come - we will pay

    Travel expenses, airfare, hotel at our expense

    The promotion is valid until December 1, 2016

  • Delivery at our expense

    When ordering the equipment in the amount of 5 mln. rub.

    The promotion is valid until December 1, 2016