+7 351 239-90-31

Outdoor switchgear and control gear – SCG

up to 10 kV
Outdoor switchgear and control gear – SCG

Request price on «Outdoor switchgear» or contact our manager a convenient way for you

Description

Outdoor switchgear and control gear (SCG) are designed for operation in 3-phase 50 Hz and 60 Hz, 6 kV and 10 kV rated AC voltage electric installations for a system with a neutral insulated or earthed via arc suppression coil, in moderate (N) and moderate cold (NF) climate, placement category 1 according to GOST 15150.

Specifications

Parameter designation Parameter value
High-voltage (HV) side rated voltage, kV 6; 10
High-voltage (HV) side maximum operating voltage, kV 7,2; 12
Rated current of main circuits, A 630; 1000; 1600; 2000; 2500; 3150
Rated breaking current of the chamber SUM with vacuum circuit breaker, kA
20; 31,5
Peak withstand current of cells with vacuum circuit breaker, kA 32; 51, 64
Rated voltage of auxiliary circuits, V:
– AC and DC protection, control and alarm circuits
– voltage measuring transformers circuits
– lighting

220
100
36

 

Symbol structure

SCGХ Х - ХХХ - Х - Х / Х - Х ХХ

SCG is a switchgear and control gear manufactured by Chelyabinsk Electric Equipment Plant LLC

O – outdoor installation

Modification: Not specified as per data sheet; Irtyash

Rated voltage, kV

Classification of lead-out on incoming line side:

  • C - cable
  • O – overhead

Classification of lead-out on outgoing line side:

  • C - cable
  • O – overhead

Rated current, A (630; 1000; 1600; 2000; 2500; 3150)

Climatic modification and placement category according to GOST15150-69

 

  • Come - we will pay

    Travel expenses, airfare, hotel at our expense

    The promotion is valid until December 1, 2016

  • Delivery at our expense

    When ordering the equipment in the amount of 5 mln. rub.

    The promotion is valid until December 1, 2016

  • Design classification

    SUM classification attributes Design
    Insulation level according to GOST 1516.3 Normal, level "b"
    Insulation type Air insulation
    Busbar insulation
    With non-insulated buses
    With insulated buses
    In term of presence of draw-out elements
    With draw-out elements;
    Without draw-out elements
    In terms of servicing conditions
    With bilateral maintenance;
    With unilateral maintenance
    In terms of installation method
    For indoor installation in electrical equipment rooms;
    For outdoor installation
    In terms of climatic modifications and placement category
    Placement category 3, climatic modification N
    according to GOST 15150, GOST 15543.1

     

    Overall dimensions

    Overall dimensions

    Overall dimensions

    Electric schematic diagram

    Electric schematic diagram

    Reviews

    ООО «Терра Груп» выражает Вам благодарность и признательность за качественную, своевременную поставку и гарантийное обслуживание оборудования – Подстанции трансформаторной комплектной на напряжение 10 кВ типа КТПН-БПКК-160/10/0,4 и за внимательный подход к поставленной задаче. Мы верим в сохранение сложившихся деловых и дружеских отношений, надеемся на дальнейшее взаимовыгодное сотрудничество. Желаем успешного развития и достижения новых вершин в бизнесе.

    Read completely

    Photo

  • Come - we will pay

    Travel expenses, airfare, hotel at our expense

    The promotion is valid until December 1, 2016

  • Delivery at our expense

    When ordering the equipment in the amount of 5 mln. rub.

    The promotion is valid until December 1, 2016